@ -0,0 +1,112 @@
|
||||||
|
esphome:
|
||||||
|
name: your-device-name
|
||||||
|
friendly_name: your-device-name
|
||||||
|
|
||||||
|
substitutions:
|
||||||
|
tx_pin: GPIO17
|
||||||
|
rx_pin: GPIO16
|
||||||
|
|
||||||
|
esp32:
|
||||||
|
board: esp32dev
|
||||||
|
framework:
|
||||||
|
type: arduino
|
||||||
|
|
||||||
|
# Enable logging
|
||||||
|
logger:
|
||||||
|
|
||||||
|
# Enable Home Assistant API
|
||||||
|
api:
|
||||||
|
encryption:
|
||||||
|
key: "YOUR-HA-API-KEY"
|
||||||
|
|
||||||
|
ota:
|
||||||
|
password: "YOUR-OTA-KEY"
|
||||||
|
|
||||||
|
wifi:
|
||||||
|
ssid: !secret wifi_ssid
|
||||||
|
password: !secret wifi_password
|
||||||
|
|
||||||
|
# I have to use static IPs, your setup might be different
|
||||||
|
manual_ip:
|
||||||
|
# Set this to the IP of the ESP
|
||||||
|
static_ip: 192.168.10.10
|
||||||
|
# Set this to the IP address of the router. Often ends with .1
|
||||||
|
gateway: 192.168.10.1
|
||||||
|
# The subnet of the network. 255.255.255.0 works for most home networks.
|
||||||
|
subnet: 255.255.255.0
|
||||||
|
dns1: 192.168.10.1
|
||||||
|
# Enable fallback hotspot (captive portal) in case wifi connection fails
|
||||||
|
ap:
|
||||||
|
ssid: "FALLBACK-AP"
|
||||||
|
password: "secretfallbackpassword"
|
||||||
|
|
||||||
|
web_server:
|
||||||
|
port: 80
|
||||||
|
|
||||||
|
# If you use Home Assistant please remove this `mqtt` section and uncomment the `api` component!
|
||||||
|
# The native API has many advantages over MQTT: https://esphome.io/components/api.html#advantages-over-mqtt
|
||||||
|
mqtt:
|
||||||
|
broker: !secret mqtt_host
|
||||||
|
# username: !secret mqtt_username
|
||||||
|
# password: !secret mqtt_password
|
||||||
|
id: mqtt_client
|
||||||
|
|
||||||
|
|
||||||
|
uart:
|
||||||
|
id: uart_1
|
||||||
|
baud_rate: 9600
|
||||||
|
tx_pin: ${tx_pin}
|
||||||
|
rx_pin: ${rx_pin}
|
||||||
|
stop_bits: 1
|
||||||
|
parity: NONE
|
||||||
|
# The increased RX buffer size is important because
|
||||||
|
# the full BMS response must fit into the buffer
|
||||||
|
rx_buffer_size: 384
|
||||||
|
# debug:
|
||||||
|
# dummy_receiver: false
|
||||||
|
# direction: BOTH
|
||||||
|
# after:
|
||||||
|
# delimiter: "\r"
|
||||||
|
# sequence:
|
||||||
|
# - lambda: UARTDebug::log_string(direction, bytes);
|
||||||
|
|
||||||
|
|
||||||
|
# Further reading: https://esphome.io/components/modbus
|
||||||
|
|
||||||
|
modbus:
|
||||||
|
# flow_control_pin: 5
|
||||||
|
# send_wait_time: 500ms
|
||||||
|
id: modbus1
|
||||||
|
uart_id: uart_1
|
||||||
|
|
||||||
|
# Further reading: https://esphome.io/components/modbus_controller
|
||||||
|
|
||||||
|
modbus_controller:
|
||||||
|
- id: modbus_device
|
||||||
|
address: 0x01 ## address of the Modbus slave device on the bus
|
||||||
|
modbus_id: modbus1
|
||||||
|
update_interval: 10s
|
||||||
|
setup_priority: -10
|
||||||
|
|
||||||
|
# Now the real works starts
|
||||||
|
# Here you have to define your registers including type
|
||||||
|
# Addresses are device specific, so you have to figure out them based on your
|
||||||
|
# modbus device. Also the type must be correct. See below link about value_types, etc.
|
||||||
|
#
|
||||||
|
# Further reading: https://esphome.io/components/sensor/modbus_controller
|
||||||
|
|
||||||
|
sensor:
|
||||||
|
- platform: modbus_controller
|
||||||
|
modbus_controller_id: modbus_device
|
||||||
|
name: "Current Power"
|
||||||
|
register_type: read
|
||||||
|
address: 0x003A
|
||||||
|
unit_of_measurement: "W"
|
||||||
|
value_type: U_WORD
|
||||||
|
- platform: modbus_controller
|
||||||
|
modbus_controller_id: modbus_device
|
||||||
|
name: "Current Energy"
|
||||||
|
register_type: read
|
||||||
|
address: 0x003C
|
||||||
|
unit_of_measurement: "Wh"
|
||||||
|
value_type: U_WORD
|