esphome:
|
||||
name: your-device-name
|
||||
friendly_name: your-device-name
|
||||
|
||||
substitutions:
|
||||
tx_pin: GPIO17
|
||||
rx_pin: GPIO16
|
||||
|
||||
esp32:
|
||||
board: esp32dev
|
||||
framework:
|
||||
type: arduino
|
||||
|
||||
# Enable logging
|
||||
logger:
|
||||
|
||||
# Enable Home Assistant API
|
||||
api:
|
||||
encryption:
|
||||
key: "YOUR-HA-API-KEY"
|
||||
|
||||
ota:
|
||||
password: "YOUR-OTA-KEY"
|
||||
|
||||
wifi:
|
||||
ssid: !secret wifi_ssid
|
||||
password: !secret wifi_password
|
||||
|
||||
# I have to use static IPs, your setup might be different
|
||||
manual_ip:
|
||||
# Set this to the IP of the ESP
|
||||
static_ip: 192.168.10.10
|
||||
# Set this to the IP address of the router. Often ends with .1
|
||||
gateway: 192.168.10.1
|
||||
# The subnet of the network. 255.255.255.0 works for most home networks.
|
||||
subnet: 255.255.255.0
|
||||
dns1: 192.168.10.1
|
||||
# Enable fallback hotspot (captive portal) in case wifi connection fails
|
||||
ap:
|
||||
ssid: "FALLBACK-AP"
|
||||
password: "secretfallbackpassword"
|
||||
|
||||
web_server:
|
||||
port: 80
|
||||
|
||||
# If you use Home Assistant please remove this `mqtt` section and uncomment the `api` component!
|
||||
# The native API has many advantages over MQTT: https://esphome.io/components/api.html#advantages-over-mqtt
|
||||
mqtt:
|
||||
broker: !secret mqtt_host
|
||||
# username: !secret mqtt_username
|
||||
# password: !secret mqtt_password
|
||||
id: mqtt_client
|
||||
|
||||
|
||||
uart:
|
||||
id: uart_1
|
||||
baud_rate: 9600
|
||||
tx_pin: ${tx_pin}
|
||||
rx_pin: ${rx_pin}
|
||||
stop_bits: 1
|
||||
parity: NONE
|
||||
# The increased RX buffer size is important because
|
||||
# the full BMS response must fit into the buffer
|
||||
rx_buffer_size: 384
|
||||
# debug:
|
||||
# dummy_receiver: false
|
||||
# direction: BOTH
|
||||
# after:
|
||||
# delimiter: "\r"
|
||||
# sequence:
|
||||
# - lambda: UARTDebug::log_string(direction, bytes);
|
||||
|
||||
|
||||
# Further reading: https://esphome.io/components/modbus
|
||||
|
||||
modbus:
|
||||
# flow_control_pin: 5
|
||||
# send_wait_time: 500ms
|
||||
id: modbus1
|
||||
uart_id: uart_1
|
||||
|
||||
# Further reading: https://esphome.io/components/modbus_controller
|
||||
|
||||
modbus_controller:
|
||||
- id: modbus_device
|
||||
address: 0x01 ## address of the Modbus slave device on the bus
|
||||
modbus_id: modbus1
|
||||
update_interval: 10s
|
||||
setup_priority: -10
|
||||
|
||||
# Now the real works starts
|
||||
# Here you have to define your registers including type
|
||||
# Addresses are device specific, so you have to figure out them based on your
|
||||
# modbus device. Also the type must be correct. See below link about value_types, etc.
|
||||
#
|
||||
# Further reading: https://esphome.io/components/sensor/modbus_controller
|
||||
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: modbus_device
|
||||
name: "Current Power"
|
||||
register_type: read
|
||||
address: 0x003A
|
||||
unit_of_measurement: "W"
|
||||
value_type: U_WORD
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: modbus_device
|
||||
name: "Current Energy"
|
||||
register_type: read
|
||||
address: 0x003C
|
||||
unit_of_measurement: "Wh"
|
||||
value_type: U_WORD
|